The “AC Loss” issue with our new alarm panel seems to be resolved, at least for now. After reprogramming the last few zones in the system, I unplugged the system and let it run on battery for several minutes. Then, I swapped out the old Ademco 4300 X-10 transformer, replacing it with the transformer that came with the new panel. When I plugged it back in, the AC Loss condition cleared up. I have a hard time believing that the transformer was the issue. I read the panel voltage across terminals 1 and 2 with both transformers, and it was exactly the same — about 16.7 volts AC. Maybe the panel was just in a confused state, and needed an actual AC power loss and recovery to “reset” itself. However, the problem did persist through several power cycles (although I’m not sure I ran the panel on battery at any point). The only way to find out for sure would be to swap the old transformer back in, and see if the problem returns. However, since it’s working now, I’m inclined to leave it alone.

I decided to try doubling my cold brew recipe this afternoon. I put 2 slightly heaping scoops of Wellsley Farms breakfast blend into the (inverted) AeroPress, added room temperature filtered water up to near the top, stirred for 1 minute, and pressed. Then, I split the concentrated coffee equally into two tumblers, topped them up to roughly 8 ounces, and added ice and a couple drops of stevia to each glass. The extra coffee made it a little bit harder to press, but it turned out just fine. I couldn’t tell any difference from my single cup recipe. The next time I do this, I may measure the total amount of water per glass more carefully, then press into a carafe or pitcher instead of directly into a tumbler.

This and that

I had hoped to take a bike ride this morning, but ended up sleeping until almost 9:00. It was probably just as well, as it’s very hot and humid today, and would have been a rather sweaty ride. The reason for my oversleeping was that we got a call around midnight from our alarm monitoring company because of a “trouble” condition. Turns out that the newer Vista panels have “trouble” reporting enabled by default, while the older ones didn’t, and I didn’t think to turn it off when I programmed the new panel. Earlier in the evening, I had popped the cover off one of the wireless contacts to check the battery, which caused the zone to go into “trouble”. I’m not sure why the alarm company called at the time they did, but it does confirm that reporting is working! The panel is still showing “AC Loss” this morning, in spite of the power being just fine. When I get to messing with it again, I’ll try unplugging it, running it on battery for a few minutes, and plugging it back in, to see if it resets. If not, I may try swapping out the transformer, and if none of that works, I’ll contact the alarm company.

The pool SWG is still reading an abnormally high temperature today. At least it’s consistent. When I get to messing with that, I’ll try re-seating the tri-sensor cable and see if it corrects itself. I may also pull the tri-sensor itself out of the manifold and take a look at it. If none of that works, I’ll test it with the tri-sensor simulator to narrow down the source of the problem, and contact my Autopilot dealer to see what he recommends. This is a rather easy issue to work around, either by calibrating the temperature reading down, lowering the Chlorine output, or turning off the setting that automatically adjusts the output based on the water temperature. Assuming I can’t fix this easily, I’m inclined to ride it out for the rest of this season, and buy any needed replacement parts over the winter.

I brewed yesterday’s dark roast coffee recipe again today, exactly the same way, except I used 180g of water instead of 200g. Truth be told, I didn’t notice much of a difference from yesterday. It was a pleasant cup of dark roast. I have enough beans to make 7 or 8 more cups, and I’m probably just going to be boring and stick with this recipe until they’re gone.